Journal of Basic and Applied Sciences  -   Volume 8 Number 2


Morphological Study and Determination of M/E Ratio in the Bone Marrow of the Male Adult Ostriches (Struthio camelus)

Mina Tadjalli, Saeed Nazifi, Behrokh Marzban and Banafsheh Majidi

http://dx.doi.org/10.6000/1927-5129.2012.08.02.40

Abstract: Normal haematopoiesis, cellular components and M/E ratio in the bone marrow of the male adult ostriches (Struthio camelus) were studied. Bone marrow samples were collected from the proximal tibiotarsus bone of 10 healthy adult ostriches. The bone marrow smears were stained using the Giemsa stain. The results indicated that the development and formation of blood cells in the bone marrow of partridge were similar to other birds. The morphology of the cells was similar to chickens, ducks, quail, and black-head gull. The mean myeloid/erythroid (M/E) ratio was 1.02, the mean erythroid percentage was 47.38%, the mean myeloid percentage was 48.15%, the mean thrombocytic percentage was 3.52% and the mean percentage of all other cells percentage was 0.99%.

Keywords: Bone marrow, Haematopoietic cells morphology, M/E ratio, Ostrich.

 

Download PDF file  :::  Back to Table of Contents

The Effect of Grain Size on Radon Exhalation Rate in Soil Samples of Dera Ismail Khan in Pakistan

Tabassum Nasir and Nisar Ahmad

http://dx.doi.org/10.6000/1927-5129.2012.08.02.29

Abstract: Radon concentration and its exhalation rate has been measured from twenty five soil samples collected from seven different locations of Dera Ismail Khan, in the north west of Pakistan. These samples were crushed after drying and passed through sieves with different sizes of pores to get three grain sizes, £0.595 mm, 0.595-2.00 mm and 2.00-4.00 mm of soil. CR-39 based NRPB (National Radiological Protection Board) radon dosimeters have been used to measure the radon concentration and exhalation rates. The maximum average value of radon exhalation rate has found to be: (3.57±0.38) Bq m-2 hr-1 in the samples having grain size 2.00-4.00 mm and the minimum as: (2.21±0.26) Bq m-2 hr-1, in the samples with grain size £ 0.0595 mm. This indicates that the radon exhalation rate increases with the grain size. The maximum average value of radon exhalation rate has been found in samples collected from river side where soil texture is silty clay loam. The obtained values of radon exhalation rate for all the samples are well below the world average value of 57.60 Bq m-2 hr-1.

Keywords: Radon concentration, Radon exhalation rate, grain size, soil texture.

Submit to FacebookSubmit to TwitterSubmit to LinkedIn